B19-T100

Contributed by Hassan Salmani; University of Connecticut

Abstract:

The Trojan trigger is a specific-vector (10110101) counter which resets with another specific vector (11111111). Whenever the counter value is between 100 and 110, the Trojan trigger becomes active. The Trojan payload is one OR gate which restitches a design net through.